GX-1

  • Shear beam load cell, one end fixed.
  • Diverse loading
  • Moisture-proof sealed – ideal for hostile environment
  • Self-centering
  • Easy to install & use
  • For floor scales, truck scales etc.
 

Capacity

Size mm

   

t

Klb

A

B

C

D

E

F

G

mm

inch

0.05-2

0.1-5se

130.0

32.0

15.7

25.4

76.2

57.0

13.5

M12X1.75

1/2-20

2.5-5

5-10

171.5

38.0

19.1

38.1

95.3

76.0

20.0

M18X1.5

3/4-16

7.5-10

15-20

222.5

50.8

25.4

50.8

123.8

102.0

27.0

M24X2

1”-14

 

Category:

Description

Specifications:

Rated Output (mV/V): 2.00±0.015 3.00±0.015  2.00±0.015 3.00±0.015
Nonlinearity:  ±0.02%FS 
Hysteresis: ±0.02%FS 
Repeatability: ±0.01%FS 
Creep (30 minutes): ±0.02%FS
Zero Balance: ±1.00%FS 
Temperature Effect on Zero: ±0.02%FS/10°C 
Temperature Effect on Output: ±0.02%FS/10°C  ±0.02%FS/10°C 
Input Resistance:  385±5Ω
Output Resistance: 350±3Ω 
Insulation Resistance: ≥5000MΩ 
Excitation Voltage:  ≥5000MΩ 
Compensated Temperature Range: -10°C ~ 50°C 
Operating Temperature Range: -20°C ~ 60°C 
Safe Overload:  120%FS 
Cable:  5.4×6 m
Cable Color Code: Input: Red (+) Black (-) Output: Green (+) White (-)